ADTF_CALIBRATION_TOOLBOX
3.11.4 (ADTF 3.18.4)
|
Plugin Filename | xcp_master_gui.adtfplugin |
---|---|
Plugin Description | xcp_master_gui.plugindescription |
Plugin Name | Qt5 XCP Master GUI Plugin (BETA) |
License | ADTF |
Support Mail | support@digitalwerk.net |
Homepage URL | https://support.digitalwerk.net/ |
Plugin Version | 3.11.4 |
---|---|
Plugin File Version | 1.0 |
adtf | 3.18.4 |
adtf::ucom | 3.1.0 |
Name | Qt5 XCP Master GUI (BETA) |
---|---|
CID | qt5_xcp_master_gui.ui_filter.calibtb.cid |
Description | The XCP GUI can be used to read and write signal values of electronic control units. |
Type | Filter |
Name | Value | Type | Description | Subproperties |
---|---|---|---|---|
Abort on Config Error | false | tBool | When activated initialization will be aborted when loading of the configuration files triggered an error | |
Allow Modification Of Read Only Signals | false | tBool | When activated, the modification of read-only signals is allowed | |
Include Raw Signal Values | false | tBool | Include Raw Signal Values from A2L in Signal List Editor | |
Start Measurement On Session Start | false | tBool | When activated, measurement will be started automatically upon session start | |
Title | $(THIS_OBJECT_NAME) | cString | Window title which will be used at runtime within Qt5 ADTF XSystem UI Service. | |
XCP Measurement UI - Configuration File | cFilename | Configuration file for the Measurement UI | Filename Extension Filter: Config File (*.json) | |
XCP Parameter UI - Configuration File | cFilename | Configuration file for the Parameter UI | Filename Extension Filter: Config File (*.par *.dcm) |
Name | Stream Type | Description |
---|---|---|
signal_updates | adtf/substreams | XCP signal value updates provided by the XCP Master Filter as Substream Has to be connected with the 'signal_updates' output pin of the 'XCP Master' - Filter. |
Name | Stream Type | Description |
---|---|---|
signal_writes | adtf/substreams | Outgoing XCP frames to the 'XCP Master' - Filter. Has to be connected with the 'signal_writes' input pin of the 'XCP Master' - Filter. |
Name | Activation Type | Data Triggered | Data Input | Thread Triggered | Thread Cyclic | Timer Triggered | Timer Interval | Description |
---|---|---|---|---|---|---|---|---|
process_signal_updates | 9 | 1 | signal_updates | 0 | 0 | 0 | 0 | Default runner port for the input pin 'signal_updates' |
Name | IID | Proxy OID | Description |
---|---|---|---|
xcp_master | xcp_master.aconcagua.calibtb.adtf.iid | Necessary connection to the 'XCP Master' - Filter Has to be connected with the 'xcp_master' interface server pin of the 'XCP Master' - Filter. |
Dynamic Input Pins | false |
---|---|
Dynamic Output Pins | false |
Dynamic Input Binding Pins | false |
Dynamic Output Binding Pins | false |
IID |
---|
qt_xsystem.spider.services.adtf.iid |