Support Request #10173
closed
Adding two output pins to one sample stream
Added by hidden over 4 years ago.
Updated almost 4 years ago.
Requester's Priority:
Normal
Description
Supportanfrage
the attached image depicts the behaviour.
Lösung
Known Problem -> ACORE-10018
Files
- Status changed from New to Customer Feedback Required
- Topic set to ADTF::CE
- Support Level changed from 2nd Level to 3rd Level
- Customer set to BOSCH
- Affected Products ADTF 3.6.3 added
Hi Bane,
adding two output pins to one sample stream => expected use case?
No, this is not valid... You always connect one Output Pin to a Sample Stream, from there you can connect to n-Input Pins
@Sebastian/Martin: I thought we already fix that ? In CE (master) there is also no error (validation) when I try this
- Status changed from Customer Feedback Required to In Progress
When launching this session, initialization will definitely fail. So yes, the CE should mark this as an error.
- Description updated (diff)
- Status changed from In Progress to Customer Feedback Required
- Resolution set to Known Problem
- Product Issue Numbers set to https://www.cip.audi.de/jira/browse/ACORE-10018
Basti sent me the known issue (ACORE-10018), scheduled for this Feature Bundle.
As Martin says, can be configured but will be declined at runtime.
So we are save but is a ugly bug for the session designer.
- Project changed from 5 to Public Support
- Subject changed from Question: adding two output pins to one sample stream => expected use case? to Adding two output pins to one sample stream
- Status changed from Customer Feedback Required to To Be Closed
- Private changed from Yes to No
- Status changed from To Be Closed to Closed
Also available in: Atom