Support Request #14870
closed
XCP Ethernet Streaming Sink is missing in Calibration Toolbox guides
Added by hidden almost 3 years ago.
Updated over 2 years ago.
Requester's Priority:
Normal
Description
Supportanfrage
In der Dokumentation der Calibration TB 3.4.0 fehlen Informationen zur XCP Ethernet Streaming Sink. Für die XCP Ethernet Streaming Source gibt es ja den Eintrag in der Doku.
Lösung
Doku ist an der Stelle unvollständig und wird im Zuge der automatischen Doxygen Generierung aufgeräumt:
- [ACALTB-673] - Create and embed component documentation generated from plugin description
Files
- Status changed from New to In Progress
- Customer set to ELEKTROBIT
- Topic set to CalibrationTB::Doc
- Affected Products ADTF Calibration Toolbox 3.4.0 added
- Platform Windows 7 64bit added
Hallo Florian,
dazu noch eine Frage von unserem Trainer:
"Maybe you could also ask in this context whether it is now official terminology to call streaming services (sources/sinks) also “filter”. Like it is done in that chapter."
Grüße,
Anja
- Status changed from In Progress to Customer Feedback Required
- Product Issue Numbers set to https://www.cip.audi.de/jira/browse/ACALTB-673
Hallo Anja,
In der Dokumentation der Calibration TB 3.4.0 fehlen Informationen zur XCP Ethernet Streaming Sink. Für die XCP Ethernet Streaming Source gibt es ja den Eintrag in der Doku.
Danke fürs Feedback, wird im Zuge der automatischen Dokugenerierung in den Toolboxen aufgeräumt:
- [ACALTB-673] - Create and embed component documentation generated from plugin description
Maybe you could also ask in this context whether it is now official terminology to call streaming services (sources/sinks) also “filter”. Like it is done in that chapter.
Basically they are because after integration of Streaming Services they are from the same base.
But due that are differing regarding trigger pipe and initialization, we still should use following terminology:
- Feed data in ADTF -> Streaming Source
- Data leave from ADTF -> Streaming Sink
- Data generating/processing -> Filter
-> The page is wrong
- Project changed from 7 to Public Support
- Subject changed from XCP Ethernet Streaming Sink is missing in Calibration tb documentation to XCP Ethernet Streaming Sink is missing in Calibration Toolbox guides
- Description updated (diff)
- Status changed from Customer Feedback Required to To Be Closed
- Private changed from Yes to No
- Department set to SUPPORT
- Resolution set to Known Problem
- Status changed from To Be Closed to Closed
Also available in: Atom
PDF