Actions
Support Request #5640
closedIdentifying the mediasample origin (source PIN) when multiple connections are merged
Status:
Closed
Priority:
Normal
Customer:
BOSCH
Department:
CC-DA/ETV
Requester's Priority:
Normal
Support Level:
2nd Level
Resolution:
Solved Issue
Product Issue Numbers:
Affected Products:
Platform:
Windows 10 64bit, Windows 7 64bit
Topic:
ADTF::Common
FAQ Links:
Description
Support Anfrage:
the scenario is the following:- A single InputPin recieves data from multiple OutputPins
- During runtime (when recieving a mediasample) I would like to identify, which Output-Pin was the sender of this mediasample
Is this possible without modifying the sending filter(s)?
Lösung:
Unfortunately this is not possible.
To solve this you would need to use multible InputPins
or
Modify the sending filter(s) as you already mentioned.
Updated by hidden over 5 years ago
- Project changed from Public Support to 5
- Status changed from New to Customer Feedback Required
- Topic set to ADTF::Common
Hello Marc Klich,
I am sorry but it looks like this is not possible.
To solve this you would need to use multible InputPins
or
Modify the sending filter(s) as you already mentioned.
Please let us know if we can close the request.
Updated by hidden over 5 years ago
Hello Marc Klich,
we haven't got any feedback.
Have you received our answer?
Can we close the request?
Regards
Matthias
Updated by hidden over 5 years ago
Hi Matthias,
thank you for the answer.
The ticket can be closed.
Best regards
Marc
Updated by hidden over 5 years ago
- Description updated (diff)
- Status changed from Customer Feedback Required to To Be Closed
- Resolution set to Solved Issue
Updated by hidden over 5 years ago
- Project changed from 5 to Public Support
- Status changed from To Be Closed to Closed
Actions