Actions
Support Request #11864
closedADTF3 restrictions regarding a2l files
Status:
Closed
Priority:
Normal
Customer:
BOSCH
Department:
Requester's Priority:
Normal
Support Level:
2nd Level
Resolution:
Solved Issue
Product Issue Numbers:
Affected Products:
Platform:
Windows 10 64bit
Topic:
CalibrationTB::XCP
FAQ Links:
Description
Support Anfrage:
ADTF2 had restrictions regarding a2l files. It was only possible to read / write raw data. Features like maps and conversion rules were not supported.
What are the restrictions regarding ADTF3 and XCP/a2l?
Lösung:
A2L Dateien sollten im Moment alle bis 1.7.1 geparsed werden. Featuremäßig wird soweit 1.6.0 unterstützt. Konvertierungen von RAW zu physikalischen Werten werden folgende unterstützt:
- LINEAR
- RAT_FUNC wenn A, D und E = 0 -> LINEAR
- FORM
Siehe auch:
Kein weiteres User-Feedback