Project

General

Profile

Actions

Support Request #11864

closed

ADTF3 restrictions regarding a2l files

Added by hidden almost 4 years ago. Updated over 3 years ago.

Status:
Closed
Priority:
Normal
Customer:
BOSCH
Department:
Requester's Priority:
Normal
Support Level:
2nd Level
Resolution:
Solved Issue
Product Issue Numbers:
Affected Products:
Platform:
Windows 10 64bit
Topic:
CalibrationTB::XCP
FAQ Links:

Description

Support Anfrage:

ADTF2 had restrictions regarding a2l files. It was only possible to read / write raw data. Features like maps and conversion rules were not supported.

What are the restrictions regarding ADTF3 and XCP/a2l?

Lösung:

A2L Dateien sollten im Moment alle bis 1.7.1 geparsed werden. Featuremäßig wird soweit 1.6.0 unterstützt. Konvertierungen von RAW zu physikalischen Werten werden folgende unterstützt:

  • LINEAR
  • RAT_FUNC wenn A, D und E = 0 -> LINEAR
  • FORM

Siehe auch:

https://support.digitalwerk.net/adtf_addons/adtf-calibration-toolbox/v3/calibrationtoolbox_html/calibtb3_page_limitations.html

Kein weiteres User-Feedback

Actions

Also available in: Atom PDF